Posted: Sun Aug 14, 2011 5:30 am
http://graflex.org/helpboard/viewtopic.php?t=5114
The 45V battery supply in the camera body operates the solenoid only. The higher voltage of two batteries in series assures longevity of the batteries and reduces the need to change batteries under heavy usage.
If you have a VOM set it to read current, .5A scale and read across the batteries with the door removed. There should be a quick high current of .1A to .2A then reduce to zero. Any current after 10 to 15 seconds is leakage in the capacitors and batteries left in the camera with the battery door on will run the batteries down in a few weeks. Taking the batteries out of the camera when it is not in use will result in the batteries lasting several months under heavy usage to a few years under light usage.
Looking at the schematic one side of the shutter contacts is common to both X and M sync, the shutter case. There are two contacts inside the Graphic 1000 shutter. The M sync contact is positioned so that it makes contact when the shutter blades are less than 1/3 of maximum open. The X sync contact is positioned so that it makes contact when the shutter blades are 99% of full open. The X-M sync lever selects which contact inside the shutter is connected to the side socket.
The batteries in the flash fire the flash bulb only when the camera button is pressed or the shutter is tripped manually. When the red button on the flash is pressed it fires the flash bulb and trips the solenoid in the camera which cannot be adjusted for flash sync like the external solenoids can.
See
http://cameraeccentric.com/html/info/graflex_12.html for operation of the Graphic 1000 shutter;
http://cameraeccentric.com/html/info/graflex_6.html for operation of the camera body.