Posted: Fri Dec 28, 2007 12:04 am
See the Top RF Pacemaker Service manual available at
http://www.southbristolviews.com/ under the Graflex Manuals link.
The tube is a complete assembly and indivual parts are not listed but some of the plungers used do have deminsions listed in the referenced manual.
The Top RF Pacemaker and Super series cameras RF tubes are the same except for the actuator plunger. (bed end).
The tube is as follows: Spring-short plunger end- CAM-long plunger-43~45 balls, 43~45 spacers in ball spacer ball configuration-actuator plunger.
Ball diamater=.1085 inch. Spacer: diamater=.085 inch, length=.106 inch, concave on each end so that a ball and spacer =.205 inch in length.
Measurements from a 43 ball, 43 spacer tube.
Best bet is find a parts body and rob the complete tube from it. Disassemble the tube, wash all balls, spacers , plungers, and the inside of the tube with a degreaser that leaves no reisdue. Coat the balls, spacers, and plungers with extra fine graphite by rolling them around in the graphite. Reassemble the tube using no other luberication. Fine graphite is too coarse/heavy to work well.