Posted: Tue Jul 24, 2007 5:58 am
Hello Philip,
Welcome to the world of Graflex Graphic cameras.
The site's help board has a search feature which will give you some results that are right to the point once in a while and a lot of tangents the rest of the time, try it sometime, but first;
1. there is a Pacemaker Service manual available for download at
http://www.southbristolviews.com/ under the Graflex Manuals link. It will tell you how to remove/reinstall the ground glass and Ektalite Field Screen.
2. Basically remove the focus hood by releasing the spring loaded retainer clips on each side of the focus hood. Remove the ground glass retainer clips by removing the two screws in each and lifting them out. Then lift the ground glass and ektalite field screen sandwich out of the focusing frame.
3. In a sink or wash pan mix some warm water and dish soap such as Dawn and insert the ground glass and ektalite field screen. Rub gently with your finger tips only both sides of the ground glass and ektalite field screen and on the ektalite field screen rub with the ridges and not across them on the ridged side. Handle by the edges only once they are clean and rince in warm water. Mix a final rince of 1/2 galon of water with 5 to 10 drops of PhotoFlow and rince each piece and allow to air dry while standing on edge. (elimates waterspots)
4. Once dry install the ektalite field screen into the focus panel with the smooth side toward the lens and the ridged side to the rear of the camera then install the ground glass with the frosted (etched) side toward the lens and the smooth side to the rear of the camera. Reinstall the retainer clips and screws tightening the screws slowly and equal number of turns to equalize the pressure on the glass. Over tightening or uneven pressure can crack the ground glass.
5. Enjoy the brighter image!
Charles