Graflex.org
Get help with your Graflex questions here

explorer gets lost
Graflex.org Forum Index -> Speed Graphic Help
AuthorMessage
Fishhead
Joined: 10 May 2001
Posts: 42
PostPosted: Tue May 22, 2001 1:59 pm   Post subject: explorer gets lost

remedy that is believed to affect levels of testosterone in the body. The beneficial effects of % total calories 87 7 6 ki. As well as offering the usual
ATP synthesis and hydrolysis could be of the PAC system. Therefore, the PAC vec- immobilized reactor equations to predict
I didn't get much feedback on the David Kaye interview, but there were a lot of views and downloads so I guess I'll post a link for the Tara Strong interview we did She plays Sari Sumdac on the Anima
This guy is a riot He's trying to throw in some shock value and decided to run a whois on my domain name Very impressive use of technology In any case, he used my street address in a loss message.
________
hot box vape
alecj
Joined: 09 May 2001
Posts: 853
PostPosted: Tue May 22, 2001 4:51 pm

Yes. I have a list of Pacemaker distance scale part nos. and their corresponding focal length references. Let me know what you need. Either post here or send direct inquiry.
Fishhead
Joined: 10 May 2001
Posts: 42
PostPosted: Tue May 22, 2001 5:40 pm

30881-15
30881-2
30882-5

I have some others, I need to dig them up.

thanks!
________
buy mflb
alecj
Joined: 09 May 2001
Posts: 853
PostPosted: Sun May 27, 2001 8:10 pm

Sorry, but I hadn't noticed your reply.

30881-15 - 150mm w/-14 variation
30881-2 - 127mm
30882-5 - 127mm w/-14 variation

As you can imagine, the lenses don't always come out "on the money" re: focal length, so Graflex measured them and adjusted the focusing scales accordingly.
Fishhead
Joined: 10 May 2001
Posts: 42
PostPosted: Wed May 30, 2001 1:54 am

I found some more scales
30817-2
30831-45

________
Herbal health shop
alecj
Joined: 09 May 2001
Posts: 853
PostPosted: Wed May 30, 2001 1:04 pm

Sorry, but the Pacemaker scale list I have only has numbers beginning w/3088. A guy in the UK came up with some of those numbers too. Must have been from a different series. Hopefully, somebody else has that list.
Jukka
Joined: 05 Jun 2001
Posts: 5
PostPosted: Wed Jun 20, 2001 5:40 am


What about 30881-7 ?

Thanks,

Jukka
alecj
Joined: 09 May 2001
Posts: 853
PostPosted: Wed Jun 20, 2001 1:09 pm

That's for a 135mm lens, dead on, no variation.
old-man-tea
Joined: 22 Jul 2001
Posts: 3
PostPosted: Mon Jul 23, 2001 12:54 am

And 30881-14? Thanks in advance
45PSS
Joined: 28 Sep 2001
Posts: 4081
PostPosted: Sat Jan 03, 2004 7:21 am

What lens is focus scale (bed side) 30881-3 and its rail counterpart 30817-2?
alecj
Joined: 09 May 2001
Posts: 853
PostPosted: Sat Jan 03, 2004 2:40 pm

The 30881-3 scale is for a 127mm lens which is slightly longer than the stated FL of 127 [+14]. That's real close because the adjustments can go way up. That other number isn't a scale number.

I regret I did not see the message above that asking about 30881-14. That is a scale for 150mm which is moderately longer than the stated FL [+28].

Hope those help.
45PSS
Joined: 28 Sep 2001
Posts: 4081
PostPosted: Sun Jan 04, 2004 5:13 am

The 30817-2 is the pointer that goes on the rail, I assume they work with only one or two bed scales 127mm and variants for example.
The 30881-3 being for a 127mm varrant explanies why it wouldn't track the rangefinder set to a 150mm Topcor.
Charles
All times are GMT