I'm tired of fighting with the Hugo Meyer RF on my pre-war Anny! It's the right model for the lens mounted, and can be set up and calibrated. But if I leave the camera in the closet for more than a week it somehow drifts out of calibration. I obtained another pre-war Anny for parts, and it has a nice Kalart RF. Anyone switch these? I haven't pulled both RFs off the bodies, but at first glance it seems that the hole through the body is drilled in a different spot. There must be installation instructions out there somewhere, and/or templates to drill the hole. Can anyone help?
Top |
|
bertsaunders Joined: 20 May 2001 Posts: 577 |  Posted: Thu Jun 17, 2004 1:46 am
post on Kalart is 3/8" down from inside top, and 1 1/16 back from face of body! 1/4" hole
post on Hugo Meyer is 11/16" down from inside top
and 7/8" back from face of body!
Bert |
|